跳到主内容

1020

1020.2

RKD 4 BG

RKD 4 BG

Double-level terminal, Screw connection, Mounting type:Mounting rail TS 35/7.5 and TS 32, Rated cross-section: 4 mm², Width: 6 mm, Colour: Beige

Download datasheet

Technical data

Rated current
32 A
Rated voltage
500 V
Rated cross-section
4 mm²
Connection principle
Screw connection
Colour
Beige
Width
6 mm
Length
60.2 mm
Mounting type
Mounting rail TS 35/7.5 and TS 32
CSA Usegroup C: rated current
25 A
CSA Usegroup C: rated voltage
300 V
CSA approval
C22.2 No 158
CSA approval granted
Yes
CSA stripping length
9 mm
CSA torque, max.
1 Nm
CSA torque, min.
0.5 Nm
CSA wire cross-section AWG, max.
12
CSA wire cross-section AWG, min.
22
Connection position
Lateral
Connections
2 x 2
Contamination degree
3
DNV GL Certificate number
TAE000014T
DNV GL Location Classes
Temperature: B, Humidity: B, Vibration: A
DNV GL approval granted
1
DNV GL rated cross-section
4 mm²
DNV GL rated current
34 A
DNV GL rated voltage
500 V
DNV GL test standard
IEC 60947-7-1:2002
EAC approval
TR ZU 004/2011
EAC approval granted
Yes
EU-POP compliant
Yes
End plate required
Yes
Flammability class UL 94
V-2
Gauge plug acc. to EN 60 947-1
A4
Height TS 32
65.5 mm
Height TS 35/7.5
61 mm
Insulating housing
Polyamide 6.6
KEMA KEUR approval
EN 60947-7-1:2009
KEMA KEUR approval granted
Yes
KEMA rated current
32 A
KEMA rated impulse voltage
6 kV
KEMA rated voltage
500 V
KEMA wire cross-section single core (rigid), min.
0.2 mm²
KEMA wire cross-section single-core (rigid), max.
4 mm²
KEMA wire cross-section stranded, max.
4 mm²
KEMA wire cross-section stranded, min.
0.2 mm²
Maximum power dissipation for nominal condition
2.05 W
Number of cross-connection channels
2
Number of levels
2
Number of terminals per level
2
Number of test pick-off options
1
Overvoltage category
III
PROP 65 compliant
Yes
REACH Candidate Substance Note
No
REACH compliant
Yes
REACH reference date
2026-02-04
Rated impulse voltage
6 kV
RoHS compliant
Yes
Screw head
Slotted
Screw threading
M 3
Stripping length
9 mm
TSCA compliant
Yes
Tightening torque, max.
1 Nm
Tightening torque, min.
0.5 Nm
UL Recognized
1
UL Usegroup C: rated current
30 A
UL Usegroup C: rated voltage
300 V
UL approval
UL 1059
UL factory wiring
Yes
UL field wiring
Yes
UL torque
7 Lb In
UL wire cross-section single-core (rigid) AWG, max.
10
UL wire cross-section single-core (rigid) AWG, min.
22
UL wire cross-section stranded AWG, max.
10
UL wire cross-section stranded AWG, min.
22
UL wire material
Cu
Weight per piece (including packaging)
14.22 g
Weight per piece (not including packaging)
13.4 g
Wire cross-section AWG, max.
12
Wire cross-section AWG, min.
22
Wire cross-section single core (rigid)/stranded, max.
4 mm²
Wire cross-section single-core (rigid) / stranded, min.
0.2 mm²
Wire cross-section stranded with wire-end ferrule, min.
0.2 mm²
Wire cross-section stranded with wire-end ferrules, max.
4 mm²
Wire cross-section stranded, max.
4 mm²
Wire cross-section stranded, min.
0.2 mm²
Working temperature, max.
105 °C
Working temperature, min.
-40 °C

Commercial data

Country of origin
CZ
Customs number
85369010
GTIN (EAN)
4044211004545

Enquire about this article

Other colours / variants

Contact us

Send us the article numbers,
we take it from there

Selection, samples, lead time, manufacturer datasheets — we reply within one working day. Or open any article and enquire there.

  • Email sales@ilerda.biz
  • Phone / WeChat 021-5433 7015
  • Address 4F Building 2, No.500 ShuHai Rd, Songjiang · P.R. China
  • Office hours Mon–Fri, 9:00–17:00
  • Operated by Shanghai ILERDA Electrical Equipment Co., Ltd.